4. Installation
Installing:
The electronic cabinet lock
SAFE-O-TRONIC
is attached on the inside of a cabinet door
using four screws.
Testing:
After installing, check the function of the
SAFE-O-TRONIC
using the TestKey.
Applying the reference plate:
Stick the user reference plate only to a flat, grease- and dust-free surface.
Configuring:
Once the installation work is complete and all the locks tested, they are configured using
the SetupKey.
5. Commissioning
5.1. Function testing with the "TestKey"
Lock
SAFE-O-TRONIC
:
1. Activate
SAFE-O-TRONIC
(push rotary knob)
2. Hold TestKey directly in front of the rotary knob.
3. When the green LED flashes, turn knob 90
°
.
Unlock the SAFE-O-TRONIC
:
1. Activate
SAFE-O-TRONIC
(push rotary knob)
2 Hold TestKey directly in front of the rotary knob.
3.
SAFE-O-TRONIC
unlocks itself.
NOTE:
The TestKey is used to test the function of factory-new or non-configured
SAFE-O-
TRONIC
. Once the SetupKey has been used to configure the
SAFE-O-TRONIC
for
the system, the
SAFE-O-TRONIC
can no longer be locked or unlocked using the
TestKey!