76
Air distribution
The compressors is supplied from factory with service valve in the air outlet (according to the table of technical features).
Do not use connection with reduction in the outlet of the compressor and do not install undersized line filter(s), so as not to cause load loss
near the source of air production. Whenever possible, install “Y” instead of “T” and long-radius curves.
We recommend installing, in the air outlet, a service line with hose and air blow gun for cleaning the radiator and other jobs that require
local compressed air.
Class 1.4.1
Class 1.4.1
SYSTEM
SYSTEM
Regular industrial air
Dry and pre-filtered
industrial air
Dry and clean industrial air
FIGURE 8.3 - TYPICAL INSTALLATION OF THE COMPRESSOR WITH PERIPHERALS FOR COMPRESSED AIR TREATMENT
1. ROTARY SCREW COMPRESSOR
2. CONDENSATE SEPARATOR FILTER
3. COALESCENT PRE-FILTER
4. REFRIGERATED AIR DRYER
5. COALESCENT POST-FILTER
6. ACTIVATED CARBON FILTER
Air quality in compliance with ISO 8573.1 - Class 1.4.1
NOTE: For other configurations, contact the factory.
In the other components, perform the maintenance according to their instruc-
tion manuals.
Note:
The installation expenses and accessories are paid by the customer.
In order not to jeopardize the quality of the compressed air, place the rotary screw compressor in such a way
that the outlet of hot air is not blown over the tank, filters and dryer (Figure 8.3).
IMPORTANT