background image

 7 

Make sure the Instant Power™ is not close to any potential source of flammable 

2. 

fumes or clothing.
Keep the Instant Power™ dry.

3. 

DO NOT allow the Instant Power™ to come into contact with rain or moisture.

4. 

DO NOT operate the Instant Power™ if you, the Instant Power™, the device being 

5. 

operated or any other surfaces that may come in contact with any power source are 

wet. Water and many other liquids can conduct electricity, which may lead to serious 

injury or death.
Do not place the Instant Power™ on or near heating vents, radiators or other 

6. 

sources of heat.
Do not place the Instant Power™ in direct sunlight. The ideal air temperature for 

7. 

operation is between 50° and 80°F.
Do not use the inverter near an open engine compartment where fumes may 

8. 

accumulate.
Do not modify the AC receptacles in any way.

9. 

Using the inverter

10.10 

It is important to know the continuous wattage of the device you plan to use with the 

inverter. The Instant Power™ must be used with devices drawing 200 watts or less. If 

the wattage is not marked on the device, use only devices that draw less than 1.7 Amps 

of AC current.

Devices like TVs, fans or electric motors require additional power to start (commonly 

known as the “starting or peak power”). The Instant Power™ can supply a momentary 

surge in wattage; however even devices rated less than the maximum 200 watts can 

exceed the inverters surge capability and cause an automatic overload shutdown.
Do not use the inverter with a product that draws a higher wattage than the inverter can 

provide, as this may cause damage to the inverter and the product.

Make sure the device you are using is compatible with a modified sine wave inverter.

 

Always run a test to establish whether the inverter will operate a 

particular piece of equipment or device.

In the event of a power overload, the inverter is designed to automatically shut down. 

This safety feature prevents damaging the inverter while testing devices and equipment 

with the 200-watt range.
If powering more than one device, start one device at a time to avoid a power surge  

and/or inverter overload. The surge load of each device should not exceed the inverter’s 

Continuous Operation wattage rate.
If you are using the power inverter to operate a battery charger, monitor the temperature 

of the battery charger for about 10 minutes. If the battery charger becomes abnormally 

warm, disconnect it from the inverter immediately.

You can use an extension cord from the inverter to the device without significantly 

decreasing the power being generated by the inverter. For best operating results, the 

extension cord should be 16 AWG (1.31 mm

2

) or larger and no longer than 50 feet.

 

This inverter uses a nonsinusoidal waveform. Therefore, we do not 

recommend you use it to power the following devices:

Switch Mode Power Supplies

1. 

Linear Power Supplies

2. 

Class 2 Transformers

3. 

Line Filter Capacitors

4. 

Shaded Pole Motors

5. 

Fan Motors

6. 

Microwave Ovens

7. 

Fluorescent and High Intensity Lamps (with a ballast)

8. 

Transformerless Battery Chargers

9. 

Doing so may cause the device to run warmer or overheat.

Summary of Contents for XJS22 INSTANT POWER

Page 1: ...and blindness Keep out of reach of children ADVERTENCIA Posible Riesgo de una explosi n El contacto con una bater a de cido puede causar quemaduras y ceguera Mant ngase alejado de los ni os READ THE...

Page 2: ...t in serious injury or death Keep out of reach of children 1 2 Do not put fingers or hands into any of the Instant 1 3 Power s outlets Do not expose the Instant Power to rain or snow 1 4 Use only reco...

Page 3: ...nal battery of the Instant Power to freeze Never charge a 2 4 frozen battery To prevent sparking NEVER allow clips to touch together or contact the same piece of metal 2 5 Consider having someone near...

Page 4: ...OR FIRE The Instant Power charger is for use on a nominal 6 1 120 volt circuit The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and o...

Page 5: ...lighter socket Completely disconnect the charger cable when the engine is not running Using this method to charge the battery overrides the maintain mode and the battery can be overcharged Monitor the...

Page 6: ...ant Power as soon as possible after use 10 Risk of Explosion To prevent sparking NEVER allow the clips to touch together or to contact the same piece of metal Never attempt to jump start a frozen batt...

Page 7: ...acturer s recommended pressures Do not leave the inflator unattended during use Ensure the battery clips are securely on the storage holders 1 Attach the corrugated hose with end adapter to the high f...

Page 8: ...use the inverter with a product that draws a higher wattage than the inverter can provide as this may cause damage to the inverter and the product Make sure the device you are using is compatible with...

Page 9: ...ts are in place and in good working 11 3 condition for example the plastic boots on the battery clips Servicing does not require opening the unit as there are no user serviceable parts 11 4 All other...

Page 10: ...Instant Power See DIGITAL DISPLAY FUNCTIONS section of this manual Have the battery checked The Instant Power won t power my 12V device The 12V device is not turned on The Instant Power battery is not...

Page 11: ...roduct Weight 23 9 lbs 10 84 kg AC Power Specifications Maximum Continuous Power 200 Watts Surge Capacity Peak Power 400 Watts No Load Current Draw 0 4 Amps Wave Form Modified Sine Wave Input Voltage...

Page 12: ...uding but not limited to express implied or statutory warranties including without limitation any implied warranty of merchantability or implied warranty of fitness for a particular purpose Further Ma...

Page 13: ...__________________ Serial Number________________________ SEE PRODUCT PROGRAMA DE REGISTRO DE 1 A O DE GARANT A LIMITADA MODELO ___________________ DESCRIPCI N ___________________________ Esta es la ni...

Page 14: ...al completo antes de utilizar este producto 1 1 Cualquier falla podr a resultar en serias lesiones o podr a ser mortal Mant ngase alejado de los ni os 1 2 No coloque los dedos o las manos en cualquier...

Page 15: ...de producir una corriente de cortocircuito lo suficientemente elevada como para soldar un anillo o provocar efectos similares sobre el metal causando una quemadura de gravedad Tenga especial cuidado p...

Page 16: ...4 3 PRECAUCIONES DE CONEXI N EN CC 5 Conecte y desconecte los ganchos de salida C C s lo despu s de haber establecido 5 1 todos los interruptores del Instant Power a la posici n de apagado si es aplic...

Page 17: ...el 100 NotA El porcentaje de carga de la bater a interna es m s confinable si el Instant Power ha sido desconectada de todos los accesorios y conexiones por unas horas Cargando la bater a interna con...

Page 18: ...la polaridad de los bornes de la bater a El borne POSITIVO POS P de 4 la bater a generalmente posee un di metro mayor al borne NEGATIVO NEG N Determine qu borne de la bater a hace descarga a tierra s...

Page 19: ...n en exceso del aparato de 12V de CD podr a descargar la bater a excesivamente Recargue inmediatamente despu s de desenchufar en aparato de 12V de CD El uso de Puerto USB 10 4 El puerto USB provee poc...

Page 20: ...lector a la posici n OFF 6 apagado y quite el adaptador Uso del desinflador 10 8 Aseg rese que las pinzas est n fijas en el compartimiento 1 Fije la manguera corrugada con la punta del adaptador de la...

Page 21: ...no por uno para evitar sobrecarga al inversor y perder energ a La absorci n de cada uno de los aparatos no debe exceder la capacidad de salida de vatios en una Operaci n Continua Si usted esta usando...

Page 22: ...5 Instrucciones para el manejo y almacenamiento 12 Guarde el Instant Power desenchufado en posici n vertical El cable seguir 12 1 conduciendo electricidad hasta que se desenchufe del toma Almacene en...

Page 23: ...nt Power Vea la secci n de los INDICADORES DE FUNCION DIGITALTIONS de este manual Haga un chequeo de la bater a La fuente de poder no pone a funcionar mi aparato de 12V El aparato de 12V no enciende L...

Page 24: ...84 kg Especificaciones de energ a en CA Energ a continua m xima 200 Watts Capacidad de la oleada energ a m xima 400 Watts Corriente no obtenida 0 4 Amperes Forma de onda Modific la onda senoidal Nivel...

Page 25: ...s expresas impl citas o legales incluidas a modo de ejemplo las garant as impl citas de comerciabilidad o adecuaci n a un fin espec fico Asimismo el Fabricante no ser responsable ante reclamos por da...

Reviews: