background image

• 8 •

4. 

Affix one or several “Ferrite Data Line Filters” to the television power cord. Ferrite Data 

Line Filters can be purchased at most electronic supply stores.

5. 

Try grounding the inverter with a minimum 18 gauge (AWG) (0.75mm

2

) wire, using as 

short a length as possible.

NOTE:

 You may hear a “buzzing” sound being emitted from inexpensive sound systems 

when operated with the inverter. This is due to ineffective filters in the sound system’s 

power supply. Unfortunately, this problem can only be resolved by purchasing a sound 

system with a higher quality power supply or higher quality filter.

7.  POWER SOURCE

When operating a device that draws approximately 60 watts, your average automobile 

or marine battery at full charge will provide an ample power supply to the inverter for 

approximately 3 hours when the engine is off. The actual length of time the inverter will 

function depends on the age and condition of the battery and the power demand being 

placed by the device being operated with the inverter.

If you decide to use the inverter while the engine is off, we recommend you turn OFF the 

device plugged into the inverter before starting the engine. To maintain battery power, start 

the engine regularly and let it run for approximately 15 to 20 minutes to recharge the battery.

Although it is not necessary to disconnect the inverter when turning over the engine, it may 

briefly cease to operate as the battery voltage decreases. While the inverter draws very 

low amperage when not in use, it should be unplugged to avoid battery drain.

8.  LED INDICATOR AND SHUTDOWN PROTECTION

The LED lights automatically when plugged into a 12 volt DC power source, but will not 

light under the following conditions:

1. 

When the power input from the vehicle’s battery drops to approximately 10.5 volts,  

low battery shutdown occurs and the inverter shuts off.  

Solution: Recharge or Replace the battery.

2. 

When the power input from the vehicle’s battery exceeds 15 volts, high voltage 

overload protection occurs.  

Solution: Reduce the voltage range to between 12 volts and 14 volts.

3. 

The continuous load demand from the equipment or device being operated exceeds 

the continuous load rating of the inverter being used.  

Solution: Use a higher capacity inverter or lower rated device.

4. 

The case temperature becomes hot (exceeds 145°F).  

Solution: Allow the inverter to cool. Do not block the cooling slots or air flow over and 

through the inverter. Reduce the load on the inverter to the continuous rated output.

RESET:

 To reset after shutdown occurs, press the On/Off button to turn the inverter OFF. 

Check the source of the problem and correct. Press the On/Off button to turn the inverter ON.

9.  LED DISPLAY

The LED display identifies the current status of the inverter.

VOLTS IN:

 The voltage of the vehicle’s battery, portable power jump starter or DC power 

source.

WATTS: 

The power or wattage supplied to the device plugged into the inverter.  

NOTE:

 The tolerance of the display is ± 15% when the output power is higher than 200 watts.

An audio alarm will sound when any of the following codes display. To stop the alarm, 

press the On/Off switch:

• OUP

 – The vehicle’s battery voltage is between 15 and 16 volts. The inverter will 

automatically restart after the voltage drops below 15.0 volts.

• OLP

 – The continuous load demand from the device exceeds the inverter’s wattage output.

• OCP

 – The inverter is overheated and automatically turns off for a period of 1 to 3 minutes 

to cool. Make sure the inverter is well ventilated. It will automatically restart after it cools.

• LUP

 – Low Voltage Alarm. The vehicle’s battery voltage is between 10.7 and 11.3 volts.

• LUP

 – Low Voltage Shutdown. The vehicle’s battery voltage is between 10.2 and 10.8 volts.

• OPP

 – Short circuit, power surge or overload in the device.

Summary of Contents for PIF-1000

Page 1: ...ique CA PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE This manual will explain how to use the converter safely and effectively Please read and follow these instructions and precautions carefully ESSAYER DE GARDER LE MANUEL D INSTRUCTIONS ET LE LIRE AVANT CHAQUE UTILISATION Ce manuel explique comment utiliser l unité d une façon sûre et efficace S il vous plaît lisez et suivez ces instruc...

Page 2: ...R TO A FLAT SURFACE 6 CONNECTING INVERTER CABLES 6 OPERATING INSTRUCTIONS 7 POWER SOURCE 8 LED INDICATOR AND SHUTDOWN PROTECTION 8 LED DISPLAY 8 IF THE INVERTER FUSE BLOWS 9 MAINTENANCE INSTRUCTIONS 9 TROUBLESHOOTING 9 ACCESSORIES 9 BEFORE RETURNING FOR REPAIRS 9 SPECIFICATIONS 10 LIMITED WARRANTY 10 WARRANTY CARD 19 ...

Page 3: ... UNE SURFACE PLATE 13 CONNEXION DES CÀBLES DE L ONDULEUR 13 INSTRUCTIONS D UTILISATION 14 SOURCE D ALIMENTATION 15 VOYANT DEL ET PROTECTION EN CAS D ARRÊT 15 AFFICHAGE À DEL 16 SI LE FUSIBLE DE L ONDULEUR SAUTE 16 CONSIGNES D ENTRETIEN 16 DÉPANNAGE 17 ACCESSOIRES 17 AVANT DE L ENVOYER POUR RÉPARATIONS 17 CARACTÉRISTIQUES 17 GARANTIE LIMITÉE 18 CARTE DE GARANTIE 19 ...

Page 4: ...NS SAVE THESE INSTRUCTIONS RISK OF ELECTRIC SHOCK OR FIRE 1 1 Keep out of reach of children 1 2 Keep the inverter well ventilated in order to properly disperse heat generated while it is in use Make sure there are several inches of clearance around the top and sides and do not block the slots of the inverter 1 3 Make sure the inverter is not close to any potential source of flammable fumes gases o...

Page 5: ...FF button 6 Remote control port Remote control sold separately 5 2 3 1 4 6 3 BEFORE USING YOUR POWER INVERTER NOTE Do not use the inverter with a product that draws a higher wattage than the inverter can provide as this may cause damage to the inverter and product When you turn on a device or a tool that runs on a motor the device goes through two stages 1 Start Up Requiring an initial surge of po...

Page 6: ... squeezing the two ridged areas 3 Remove the nut and bolt from the terminal 4 Slide the red protective cover over the red cable in the correct orientation 5 Using the nut and bolt you removed attach the red cable to the positive terminal Tighten the terminal so that the cable cannot come loose but do not over tighten 6 Remove the black negative plastic cover by squeezing the two ridged areas 7 Rem...

Page 7: ...ON OFF switch to turn off the alarm If the OPP displays after several attempts there is a short circuit or the device requires more starting or peak load than the inverter is capable of providing IMPORTANT If you are using the power inverter to operate a battery charger monitor the temperature of the battery charger for about 10 minutes If the battery charger becomes abnormally warm disconnect it ...

Page 8: ...tely 10 5 volts low battery shutdown occurs and the inverter shuts off Solution Recharge or Replace the battery 2 When the power input from the vehicle s battery exceeds 15 volts high voltage overload protection occurs Solution Reduce the voltage range to between 12 volts and 14 volts 3 The continuous load demand from the equipment or device being operated exceeds the continuous load rating of the...

Page 9: ... does not require opening the unit as there are no user serviceable parts 11 5 All other servicing should be performed by qualified service personnel 12 TROUBLESHOOTING PROBLEM REASON SOLUTION Audible alarm is on and or inverter does not function Poor contact at terminals Fuse blown Inverter shutdown Check connections at power supply See IF THE INVERTER FUSE BLOWS section See LED INDICATOR AND SHU...

Page 10: ... or replacement to occur Manufacturer does not provide any warranty for any accessories used with this product that are not manufactured by Schumacher Electric Corporation and approved for use with this product This Limited Warranty is void if the product is misused subjected to careless handling repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthoriz...

Page 11: ...es de la reproduction Californie loi exige cet avertissement à donner à des clients dans le État de la Californie Lavez vous les mains après toute manipulation 1 INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ CONSERVER CES INSTRUCTIONS RISQUE DE CHOC ÉLECTRIQUE OU D INCENDIE 1 1 Ne le laissez pas a la portée des enfants 1 2 Pour une efficacité d utilisation maximale mettre l onduleur sur une surf...

Page 12: ...hargeur 1 21 Ce chargeur emploie des pièces comme les sélecteurs et les disjoncteurs qui ont tendance à produire des arcs et des étincelles Si utilisé dans un garage placer ce onduleur 18 inch 45 72 cm ou plus au dessus du niveau d étage 1 22 Ne modifiez pas l onduleur avec un produit ayant une puissance plus élevée que l onduleur peut fournir toute modification peut entraîner des dommages à l ond...

Page 13: ...utes avec un transformateur 9 Chargeur sans transformateur 4 FIXATION DE L ONDULEUR SUR UNE SURFACE PLATE Pour votre convenance l onduleur peut être fixé sur une surface plate horizontalement ou verticalement La zone où l onduleur est fixé doit être sèche bien ventilée et à l abri de toute matière combustible ou émanations 1 Éteignez et débranchez l onduleur 2 Placez l arrière de l onduleur avec l...

Page 14: ...ez le commutateur MARCHE ARRÊT On Off de l onduleur sur la position ON 3 Le voyant lumineux DEL s allumera pour vérifier que l onduleur est alimenté en courant 4 Basculez le commutateur MARCHE ARRÊT On Off de l onduleur sur la position OFF Le voyant lumineux DEL peut clignoter brièvement et ou le haut parleur interne peut émettre un bref bip C est normal 5 S assurer que l appareil devant être util...

Page 15: ...tant une chaine stéréo de meilleure qualité ou ayant un meilleur filtre 7 SOURCE D ALIMENTATION Lorsque vous utilisez un appareil ayant une puissance d environ 60 watts votre batterie marine ou automobile habituelle à pleine charge apportera suffisamment de courant à l onduleur pour une durée d environ 3 heures lorsque le moteur est éteint La durée réelle de fonctionnement de l onduleur dépendra d...

Page 16: ...eur OCP L onduleur surchauffe et se coupe automatiquement de 1 à 3 minutes pour refroidir S assurer que l onduleur soit bien ventilé Il redémarrera automatiquement une fois refroidi UP Alarme de basse tension La tension de la batterie du véhicule s abaisse entre 10 7 et 11 3 volts UP Arrêt en cas de basse tension La tension de la batterie du véhicule tombe entre 10 2 et 10 8 volts OPP Court circui...

Page 17: ...U RETOUR communiquer avec le Service à la Clientèle au 1 800 621 5485 NE PAS ENVOYER L UNITÉ jusqu à ce que vous recevez une AUTORISATION DE RETOUR RMA auprès de Service à la clientèle Schumacher Electric Corporation 15 CARACTÉRISTIQUES Puissance continue maxi 1000 Watts Capacité de surtension pic de puissance 2000 Watts Pas de tirage de charge 0 6 A Forme d ondes de sortie Sinusoïdale modifiée Fo...

Page 18: ...n par une personne autre que le fabricant ou si cet appareil est revendu au travers d un détaillant non autorisé Le fabricant ne fait aucune autre garantie y compris mais sans y être limité expresse implicite ou garanties légales y compris mais non de façon limitative toute garantie implicite de valeur marchande ou de pertinence pour un usage particulier De plus le fabricant ne peut être tenu resp...

Page 19: ...__ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For faster warranty activation go to www batterychargers com to register your product online INSCRIPTION AU PROGRAMME DE GARANTIE LIMITÉE DE 1 AN MODÈLE _____________________DESCRIPTION _________________________ Ceci représente la se...

Reviews: