_________________________________________________________________________________________
schunk.com
XND.00033.002_B – 05/2022
28
6
Troubleshooting, eliminating faults
Clamping using the lateral clamping screw (pos. 230) is not possible
The clamping element on the inside is not in the correct position.
See
Section 8 Assembly
Unable to disassemble the carriage unit from the base body
Unscrew the clamping screw. (pos. 230)
Remove the central jaw and blow-out the body through the blow-out holes on the front
carriager. (pos. 70)
Important:
Vice functions can exclusively be guaranteed if the central jaw has been installed.
Cylinder screw (pos. 160) has not been removed.
7
Removal
Removing the carriage unit
Removing the system jaws.
Remove the cylinder screw (pos. 160).
Undo the clamping screw (pos. 230) by a minimum of 4 turns.
Cylinder screw (pos. 40) must never be unfastened.
Pull the entire carriage unit from the base body.