Assembly
18
06.00 | KTG | Assembly and operating manual | en | 389181
4.2 Air connection
NOTE
• Observe the requirements for the compressed air
supply,
.
• In case of compressed air loss (cutting off the energy line), the
components lose their dynamic effects and do not remain in a
secure position. However, the use of a SDV-P pressure main-
tenance valve is recommended in this case in order to main-
tain the dynamic effect for some time. Product variants are
also offered with mechanical gripping force via springs, which
also ensure a minimum clamping force in the event of a pres-
sure drop.
1
Hose-free direct connection at the base
(a = open, b = close)
2
Main connections (Hose connection)
(A = open, B = close)
Hose-free direct connection
3
Attachment
4
O ring
5
Product
• Only open the air connections required.
• Seal those main air connections that are not needed using the
locking screws from the accessory kit.
• Seal any air connections not required using threadlocker
(Loctite 582 or similar).
• For hose-free direct connections, use the O-rings from the
accessory kit.