Troubleshooting
20
02.02|AGE-F-XY 31-80|en
Troubleshooting
Module does not move?
Possible cause
Corrective action
Setscrew/stop screw screwed in too deep
Use a shorter stop screw
(
7.3, Page 14)
Setscrew for spring adjustment screwed in
too far
Turn back the setscrew (50)
(
7.4, Page 16)
Magnetic switch (MMS) does not work / cannot be adjusted
Possible cause
Corrective action
Steel screws used for fastening the compen-
sation unit
Replace steel screws with high-alloyed
screws
Mounting plates, angle brackets etc. from
magnetizable materials
Check, replace with nonmagnetizable parts
– perhaps use aluminum or plastic
8
8.1
8.2