Assembly
14
04.00 | AGE-S-XYZ | Assembly and Operating Manual | en | 389004
Special Connection
Dimensions
The compensation units are equipped with interfaces in
accordance with ISO/DIS 9409-1
Type
Interface
AGE 100
ISO 9409-1-100-6-M8
AGE 125
ISO 9409-1-125-6-M10
AGE 160
ISO 9409-1-160-6-M10
AGE 200
ISO 9409-1-200-6-M12
5.2 air connection / media connection
For the connection dimensions, see the relevant drawings in the
latest catalog or our CAD data service on the Internet
(www.schunk.com).
WARNING
Risk of injury in case of unexpected movements of machine/
system
•
The power supply must be switched off when connecting.
"Basic safety instructions"
NOTE
• Observe the requirements for the compressed air supply,
• In case of compressed air loss (cutting off the energy line), the
product loses its dynamic effects and does not remain in a
secure position. However, the use of a SDV-P pressure
maintenance valve is recommended in this case in order to
maintain the dynamic effect for some time.
NOTE
• Only open the required connections.
• For hose-free direct connections, use the O-rings from the
accessory kit.
• Seal air connections which are not required using suitable
locking screws.