Maintenance
36
01.00 | AGE-U | Assembly and Operating manual | en | 1393226
8 Maintenance
8.1 Maintenance intervals
Maintenance
interval
Maintenance work
weekly
Clean all parts thoroughly, check for damage
and wear, if necessary replace seals and
wearing parts
Check all compressed air connections and
lines and cables for damage, abrasion and
wear,
Tighten the connections and secure the
cables so that they allow sufficient freedom of
movement during operation and do not rub
or block other components.
Check workpiece stop, overload pins and
conical compression springs for damage and
wear, replace if necessary,
overload pins, compression springs and
workpiece stop
8.2 Removing the product from the robot arm
WARNING
Risk of injury due to sudden movements!
If the energy supply is switched on or if residual energy is still
present in the system, this can cause components to move
unexpectedly, which may result in serious injuries and material
damage.
•
Before starting any work on the product: Switch off the energy
supply and secure against re-connection.
•
Ensure that no residual energy remains in the system.
•
Secure components from falling down or over.
Ø
Switch off and deactivate all activated supply circuits (e.g.
electrical, air, water, etc).
Ø
Disconnect the compressed air lines and sensor cables from the
connections.
Ø
Loosen the screws (5) and remove the end effector (4).
Ø
Support the product (3) and use a hexagon socket wrench to
loosen the locked screws (2) that fasten the product to the
robot (1) or adapter plate.
Ø
Remove the product (3).