5.4 Mounting the MMS 22 magnetic switch
NOTE
Observe the assembly and operating manual of the sensor for
mounting and connecting.
NOTICE
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
Ø
Connect the sensor (1), see Sensor Assembly and Operating
Manual.
Ø
Place the product in the centered home position,
Ø
Slide the sensor (1) into the groove (2).
Ø
Pull the sensor (1) back again slowly until it activates.
Ø
Secure the sensor (1) using the set screw (3).
Tightening torque: 10 Ncm
Ø
Bring the product into position and test for proper functioning.