Technical data
12
03.00 | AGE-XY | Assembly and operating manual | en | 389007
3 Technical data
Size
50
63
80
Locking force at 6 bar [N]
235
370
580
Compensation stroke [mm]
±2.5
±3
±4
Max. distance of displacement force in Z
[mm]
120
160
200
Min. pressure [bar]
Max. pressure [bar]
2
8
Min. ambient temperature [°C]
Max. ambient temperature [°C]
+5
+60
Noise emission [dB(A)]
≤70
Pressure medium
Compressed air, compressed air quality
according to ISO 8573-1:7 4 4
Repeatability [mm]
0.1
More technical data is included in the catalog data sheet.
Whichever is the latest version.
NOTE
Owing to the design, the compensation unit may also have a
clearance of approx. 0.06 even in locked state. Twisting in locked
state is possible up to a dimension of 0.1°.
Rigid centric locking can therefore not be guaranteed.