Troubleshooting
03.00 | CLM | Assembly and operating manual | en | 389015
27
6 Troubleshooting
6.1 Module does not move
Possible cause
Corrective action
Pressure drops below minimum.
Check air supply.
[
Compressed air lines switched.
6.2 End position does not exist
Possible cause
Corrective action
Sensor set to the stop inaccurately
19].
Proximity switch defective or set incorrect.
Change sensor.
Cable breakage.
Replacing the sensor cable.
6.3 Linear module proposes at the end positions
Possible cause
Corrective action
Damping wrong adjustet.
Adjust stop screw.
Shock absorber defective.
Change the shock absorber.
Stroke speed too high.
Check / reduce stroke speed with ventilation
valves.
Change defective exhaust ait throttle if
necessary.
6.4 Payload swings in the final position
Possible cause
Corrective action
Stroke speed too high.
Check / reduce stroke speed with ventilation
valves.
Change defective exhaust ait throttle if
necessary.
Bad damping.
Unfavorable installation.
Check construction.
CLM size too small
Use larger CLM size.