Design and description
30
03.00 | EGI | Assembly and Operating Manual | en | 1396645
4.4.4 Service interface
NOTE
Only SCHUNK service engineers may access the SERVICE interface.
Do not remove the cover plug (1).
Service interface
1
Service interface cover plug
4.5 Types of communication of PROFINET
The product supports the communication types:
•
TCP/IP:
Open Ethernet TCP/IP communication without real time
requirements
•
RT (Real Time):
IO data exchange between automation devices in real time
(>1 ms).
•
IRT (Isochronous Real Time):
– Smallest supported network cycle time 0.25ms = 250μs
– Synchronization of the application not possible
The product is incorporated into the PROFINET network as an IO
device.