Assembly and settings
32
03.00 | EGI | Assembly and Operating Manual | en | 1396645
5 Assembly and settings
5.1 Assembling and connecting
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
NOTE
A temperature malfunction may occur if the product reaches
excessively high temperatures.
• Ensure sufficient heat dissipation via the customer's mounting
surface.
• Mount the product so that sufficient cooling is guaranteed.
• The size of the cooling surface depends on the application.
Avoid exposure to additional heat e.g. caused by attachments
or by the attached axles.
Overview
Ø
Check the evenness of the mounting surface,
33].
Ø
Choose the installation position so that connection cables are
not damaged or cannot wrap around the product when
swiveling.
Ø
Screw the product to the machine/system,
33].
✓
Use suitable connecting elements (adapter plates) if
necessary.
If required, adapter plates can be requested from SCHUNK.
✓
Observe the maximal tightening torque, admissible screw-in
depth and, if necessary, strength class.
Ø
Secure the gripper fingers to the base jaws,
34].
✓
Observe the maximal tightening torque, admissible screw-in
depth and, if necessary, strength class.
Ø
Connect the ground cable between the product and the
machine/system,
Ø
Place the voltage supply cable on the connector and screw the
threaded ring tightly by hand,
35].