Technical data
22
04.00 - FW 2.x | EGL | Assembly and Operating Manual | en | 389661
Depending on the ambient temperature, continuous gripping is
only permitted with reduced motor current. Otherwise the
product will overheat and signal a malfunction.
To determine the nominal gripping force, the product is installed
with a positive locking on an aluminum plate. The 200x200x20
mm³ large aluminum plate is isolated to the ground. With an
ambient temperature of 22 °C, the product can hold with the
nominal gripping force for at least 5 hours.
v-L diagram
The v-L diagram shows the maximum finger length according to
the set motor current and the process speed. If the maximum
finger length is exceeded, the guides will wear prematurely.