Assembly
02.00 | ELM | Assembly and operating manual | en | 389058
21
4.2 Assembly of position measuring system WSM
The position measuring system is delivered in disassembled state
and must be assembled as described in the following figure:
Mounting of position measuring system
Designation
WSM 23-H70
WSM 37-H...
A
Clearance of reading head from
magnetic tape [mm]
0.3 ±0.1
0.3 ±0.1
B
Position of magnetic tape [mm]
7
27,5
■
The bolting surfaces must be clean and undamaged and the
support surface for the magnetic tape must be free of dirt and
grease.
Ø
Bolt the sensor bracket (5) to the base body using cylindrical
screws (4).
Ø
Bond the magnetic tape (1) flush with the outer edge of the
module to the base body (self-adhesive) as in the Figure.
Ø
Bolt the magnetic sensor (3) to the sensor bracket (5) using
cylindrical screws (2).and set the clearance from the reading
head to the magnetic tape (A).