Assembly
03.00 | GSM-W | Assembly and operating manual | en | 389108
29
• The right rotating angle end position is always reached, when a
swichting point of the sensor of the right groove (SGR1 or SGR2)
is active.
The sequence of the swivel and closing movements (process
sequence) defined during the teach process must also be followed
during operation. Otherwise, incorrect sensor signals may be
outputted.
• If you require further information on sensor operation, contact
your SCHUNK contact person or download information from our
homepage.
• Technical data for the sensors can be found in the data sheets
(included in the scope of delivery).
5.4 Mounting a customized construction
NOTICE
Damage to the unit during assembly!
When inserting the cylindrical pins or centering sleeves, the unit
must not be subjected to any impact.
Mounting of a customized construction to the gripper fingers
GSM-W
It is recommended to use the width of the gripper finger which is
designed as the fit size for the centering of the customized top
jaws. It is also recommended to use the upper contact surface of
the gripper finger to support the customized top jaws.
No mounting screws are included in the scope of delivery.