5.3.4 Mounting inductive proximity switch IN 40
Installing the sensor
1. Remove standard holder.
Installing the sensor with mounting kit
2. Fasten the switching lug (1) with screw (2) horizontally on the
right gripper finger.
3. Insert sensor (3) from below into holder (5).
4. Insert the screws (4) into the holder (5).
5. Place the holder (5) onto the holder (7) from above and screw
the screws (4) to the clamping plate (8).
6. Secure holder (7) to the product with the screws (6).