Assembly
30
05.00|21151452 KSP plus-IN, KSP-LH plus-IN, KSP plus-IN2, KSP-LH plus-IN2 |en
IN2 sensor assembly
Test the function by clamping and opening the clamping system. If
necessary, adjust the switching position. Then link the plug
connection between the proximity switch and connecting cable.
NOTE:
The sensor head of the proximity switches may not touch the base
jaws under any circumstances in the operating condition. Both
proximity switches must be installed in the operating condition to
prevent chips from entering the clamping system through the
open clamp.