Maintenance and care
05.00|21151452 KSP plus-IN, KSP-LH plus-IN, KSP plus-IN2, KSP-LH plus-IN2 |en
37
Maintenance and care
The item numbers specified for the corresponding individual
components relate to chapter drawings.
Regularly check inductive proximity switches for proper
functioning. Check for damage to connection cables, connection
plugs and the sensor head.
The base jaws (2), chuck piston (3) and housing (1) are made to go
together. To replace these parts, ship the entire clamping system
to SCHUNK along with a repair order.
Please observe the following instructions in order to keep the
clamping system operating smoothly:
• Make sure the bore hole for coolant drainage remains
unblocked!
• Lubricate the guides on the two front or the two side
lubricating nipples with LINOMAX 200 depending on load, but
at least once per month or every 10,000 clamps. Make sure the
chuck jaws are in the open position.
• Disassemble the base jaws and the chuck piston at least once
every three months (or more often, if necessary). Clean the
housing, base jaws and chuck piston, and lubricate all the
guides (housing, base jaws, chuck piston) with LINOMAX 200.
Reassemble everything and relubricate the two front or two
side lubricating nipples with LINOMAX 200.
(Product information for LINO MAX 200 can be requested from
SCHUNK).
CAUTION
Allergic reactions due to grease in contact with skin!
Wear gloves.
IMPORTANT!
Please regularly check the clamping device for tightness by
applying a clamping force tester over a longer period of time (>10
min.). The clamping force should not drop during this period.
Please adjust the inspection interval to the operating conditions of
the clamping device, however, we do recommend conducting a
check every 5,000 clamping cycles at the latest.
7