Assembly
08.00 | PFH 150- 300 | Assembly and Operating Manual | en | 389270
27
4.3.2 Magnetic switch MMS 22 / RMS 22
brown
black
blue
load
closer
CAUTION
Sensor can be damaged during assembly.
Do not exceed the maximum tightening torque of 30 Ncm for the
set screws.
NOTE
Ferromagnetic material changes the switching positions of the
sensor. For example: Adapter plate made of ordinary steel.
At ferromagnetic adapter plates:
• First mount the product on the adapter plate.
• Then set the position of the magnetic switch.
The RMS sensors have a larger hysteresis than the MMS sensors.
This means that short gripper strokes may not be able to be
monitored with the RMS sensors.