Assembly
38
13.00 | PGB | Assembly and Operating Manual | en | 389275
4.2.13 Mount flexible position sensor FPS-M8
To be able to mount the sensor, the gripper has to be retrofitted
with a special mounting kit.
1. Move product to the "gripper open" position.
2. Loosen screw (4) and remove control cam (6) for the inductive
monitoring from the base jaw.
3. Remove screw (5) from the base jaw.
4. Slide control cam (7) from the mounting kit with the recess at
the front into the base jaw.
5. Screw the control cam (7) to the base jaw using the screw (8).
6. Slide spacer shim (9) into the bracket (2) to the stop.
7. Slide the sensor (1) to the stop into the bracket (2).
8. Tighten the screw (3) on the bracket (2).
Tightening torque: 0.2 Nm
9. Adjust sensor (1), see assembly and operating manual of the
sensor.