Maintenance
10.00 | PGN-plus-P | Assembly- and Operating Manual | en | 389753
53
7.5.3 Replace seal (variant with gripping force maintenance "I.D.
gripping")
Ø
Remove all compressed air lines,
23].
Ø
Remove product from the system/machine.
Ø
Variant Dust-tight (SD):
Ø
Remove the cover (11).
Ø
Mark the installation position of the base jaws (3) on the
housing (10).
Ø
IMPORTANT! Cover (5) is under spring tension. Remove
carefully.
Carefully unscrew the screws and remove the cover (5) and the
spring (7).
Ø
Unscrew screw (8) and take cylinder piston (4) out of the
housing (10).
Ø
Push the wedge hook (1) out of the housing (10).
Ø
Take base jaws (3) out of the housing (10).
Ø
Remove old seals (2, 6 and 9).
Ø
Clean guiding areas.
Ø
Attach new seals (2 and 9) from the seal kit.
Ø
Re-lubricating guiding areas
Ø
Insert base jaws (3) into the housing (10).
IMPORTANT! Observe installation position of the base jaws (3)
in the housing (10).
Ø
Insert wedge hook (1) into the housing (10).
Ø
Insert cylinder piston (4) into the housing (10) and tighten screw
(8). Secure the screw with medium-strength threadlocker.
Tightening torque:
Ø
Insert spring (7) into the housing (10). In doing so, observe the
alignment of the spring in relation to the cylinder piston.
Ø
Insert flat gasket (6).