Assembly
6.2.2 Pneumatic connection
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
NOTICE
Damage to the gripper is possible!
If the maximum permissible finger weight or the permissible
mass moment of inertia of the fingers is exceeded, the gripper
can be damaged.
•
A jaw movement always has to be without jerks and bounce.
•
You must therefore implement sufficient reduction and/or
damping.
•
Observe the information in the catalog data sheet.
NOTE
• Observe the requirements for the compressed air
supply,
.
27