Maintenance
36
02.00 | PLG | Assembly and Operating Manual | en | 1517334
8 Maintenance
8.1 Safety
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
CAUTION
Risk of injury from lifting heavy loads!
Lifting, holding and carrying products with a heavy weight – espe-
cially in awkward postures – can lead to back disorders and injuries.
•
Use appropriate aids to lift and handle the product.
•
Take safety measures that prevent the product from falling.
•
Wear suitable protective equipment.
Original spare parts
Use only original spare parts of SCHUNK when replacing spare and
wear parts.
8.2 Observation of the maintenance and lubrication intervals
NOTICE
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.
Maintenance
interval
Maintenance work
0.5 million cycles
or every 6 months
Treat all grease areas with
lubricant,
daily
For short gripping strokes (< 30 mm): Travel
an entire stroke.
regularly
Dry clean all parts thoroughly, check for
damage and wear.
Remove coarse contamination such as chips
and debris.
Oil or grease external steel parts.