Technical Data
18
06.00 | PPU-P | Assembly and Operating Manual | en | 389323
3.1 Anti-fall device
Designation
PPU-P 10
PPU-P 30
Static holding force [N]
80
180
Max. axial play of clamp [mm]
0.2
0.2
Min. release pressure [bar]
3
3
Pneumatic connection
M5
M5
3.2 Valve and control specifications
Designation
PPU-P 10
PPU-P 30
directional control valves 4 x 3/2 directional
control valve
monostably vented
4 x 3/2 directional
control valve
monostably vented
Nominal flow
200 l/min
400 l/min
response time "on"
28 ms
28 ms
Response time "off"
8 ms
8 ms
Recommended cycle
time of the PLC *
< 1 ms
< 1 ms
* If the digital input signals are wired directly to the PLC input
module, make sure that this does not exceed a maximum cycle
time of
5 ms
. Due to the speed of the PPU-P, the PLC cannot
record any input signals and if the cycle time is exceeded,
malfunctions may occur.