Assembly
06.00 | PPU-P | Assembly and Operating Manual | en | 389323
21
4.2 Attachment of loads
Loads can be mounted on the cantilever arm on the front end or
from below.
Centering elements for fastening loads
Item Designation
ID number
PPU-P 10
PPU-P 30
100 * Centering sleeve
0313367
0313368
* included in scope of delivery
CAUTION
•
Please note the permissible range of the center of mass of the
load.
•
Always mount loads with the cantilever arm
retracted
!
•
Select the suitable screw tightening torque for mounting of
the loads on the unit in accordance with the generally
applicable directives for screw connections.
•
When mounting loads, only the maximum permissible
moments can be applied to the cantilever arm – no forces!