Assembly
06.00 | PPU-P | Assembly and Operating Manual | en | 389323
33
Adjusting sensors for
VE and VA end
positions
■
The back stops of the end positions have been set,
Adjustment of vertical end positions
■
The unit has been depressurized.
Ø
Unscrew the cover plate of the paneling.
Ø
Approach rear end position manually (extension arm retracted).
Ø
Push the VE sensor against the control cam from below until
there is a signal at the output.
NOTE
Observe the Y switching distance when fastening the counter
nuts.
Switching distance Y is preadjusted at the factory via two hexagon
nuts.
Ø
Approach front end position manually (extension arm
extended).
Ø
Push the VA sensor against the control cam from below until there is
a signal at the output.
Ø
Secure position by tightening the sensor.
Adjusting sensors for
UV and UH switching
points
■
Back stops of the vertical end positions have been adjusted,
Adjustment of vertical end positions
■
Sensors of end positions have been adjusted (see above).
■
The unit has been depressurized.
Ø
Unscrew the cover plate of the paneling.
Ø
Approach the top position of the cycle movement manually.
Ø
Push the UV sensor against the control cam from above until
there is a signal at the output.
NOTE
Observe the Y switching distance when fastening the counter
nuts.
Switching distance Y is preadjusted at the factory via two hexagon
nuts.
Ø
Set the UH sensor at a distance of X to the upper end position,
Mounting and adjustment of sensors IN
Ø
Secure position by tightening the sensor.