Maintenance
50
06.00 | PPU-P | Assembly and Operating Manual | en | 389323
7.5 Replace clamping cartridge
CAUTION
In event of dynamic load, the clamping cartridge can be
damaged, and must be replaced if necessary.
Dynamic load at pressure drop can not be avoided in operation.
Replace clamping cartridge
Item
Designation
ID number
PPU-P 10
PPU-P 30
2
Rod
5520567
5522706
3
Clamping cartridge
9955686
9954333
Disassembly
Ø
remove air connection M5 (1).
Ø
unlock thread.
Ø
Unscrew rod (2) from thread and remove it from the hole.
Ø
Remove clamping cartridge (3).
Assembly
Assemble clamping cartridge, as described in chapter "Mounting of
optional anti-fall device ASP-P..."