Handling and operation
38
06.00 | PPU-P | Assembly and Operating Manual | en | 389323
5 Handling and operation
5.1 Delivery state
All components required for operation are factory-installed:
• The shock absorbers are preset for safe operation
• Throttles of connections A and B (vertical drive) are closed
• Throttles of connections C and D (horizontal drive) are closed
• Sensor positions are not preadjusted
• End positions are set to maximum stroke
5.2 Commissioning
5.2.1 Steps for commissioning
• Check the Technical Specifications
Attachment of loads.
• Do not use the unit until you have determined that it is in
perfect operating condition, after having checked for
compliance with all permissible operating parameters.
Further information
2
5.2.2 First steps
Proceed as follows to commission the unit.
Ø
Adjust horizontal end positions,
Ø
Adjust vertical end positions,
Ø
Mounting and adjustment of sensors IN
32].
Ø
Adjust the regulator valves,
Adjustment of regulator valves
For this purpose, allow the unit to operate in standard sequence,
39].
Ø
Adjust shock absorbers,
35].
For this purpose, allow the unit to operate in standard sequence,
Ø
If necessary, readjust shock absorbers and regulator valves.
✔
Adjustment of the unit is now complete.