Assembly
08.00 | PZB-plus | Assembly and Operating Manual | en | 389366
31
5.3.9 Mounting the reed switch RMS 80
CAUTION
Blockade of the gripper after setting or replacing of the
switching cam!
The switching cam can be tilt in the guide, if it was not fixed
exactly in the base jaw.
•
Apply the switching cam in the direction of the base jaw, so
that the cam does not contact the housing of the gripper.
Position "Gripper open" or "Part gripped (I.D. gripping)"
Ø
Slide the sensor 1 (1) or sensor 2 (1) to the stop into the bracket
(2).
Ø
Tighten the screw (3) on the bracket (2).
Tightening torque: 0.2 Nm
Ø
Open gripper or grip part.
Ø
Undo the screw (4).
Ø
Turn the screw (5) to push the position of the control cam (6).
✓
Slide control cam (6) inwards until the sensor 1 (1) no longer
responds.
Move the control cam (6) back towards the outside until the
sensor 1 (1) begins to switch.
Ø
Tighten screw (4) and in doing so press the control cam in the
direction of the gripper fingers.
IMPORTANT! The control cam
may tilt in the guide if it has not been tightened properly.
✓
Switching point is set.
Ø
Bring product into the "Gripper open" or "Part gripped" position
and test the function.