Troubleshooting
02.00|PZH-plus 020-075|en
33
Product opens or closes abruptly
Possible cause
Corrective action
Too little grease in the mechanical guiding
areas.
Clean and lubricate product.
Compressed air lines blocked.
Check compressed air lines of damage.
Screw-on surface is not sufficiently flat.
Check the evenness of the bolting surface.
One-way flow control valve is missing or ad-
justet incorrectly.
Install and adjust one-way flow control valve.
Loading too large.
Check permissible weight and length of the
gripper fingers.
The gripping force is dropping
Possible cause
Corrective action
Compressed air can escape.
Check seals, if necessary, disassemble the
product and replace seals.
To much grease in the mechanical movement
space.
Clean and lubricate product.
Pressure drops below minimum.
Check air supply.
Link Pneumatischer Anschluss
Component part defective.
Replace component or send it to SCHUNK for
repair.
6.3