Assembly
Part gripped (O.D. gripping):
1. Clamp the part to be gripped.
2. Push the magnetic switch 2 (2) into the groove towards the
middle of the gripper until it switches.
3. Tighten the set-screw (3) to clamp the magnetic switch 2 (2) in
this position in the groove.
4. Open and close the gripper to test its function.
Part gripped (I.D. gripping):
1. Clamp the part to be gripped.
2. Push the magnetic switch 1 (1) into the groove until it stops at
the end of the groove.
3. Pull the magnetic switch 1 (1) back again slowly until it
switches.
4. Tighten the set-screw (3) to clamp the magnetic switch 1 (1) in
this position in the groove.
5. Close and close the gripper to test its function.
27
06.00 | PZH-plus | Assembly and Operating Manual | en | 389504