Maintenance
36
06.00 | PZH-plus | Assembly and Operating Manual | en | 389504
7.4 Disassembly of the module
Position of the item numbers
Assembly tools are needed for
disassembly
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
1. Close the gripper and remove the compressed air lines.
2.
Remove the cover (15) and unclamp the eccentric (9). To do
this, rotate the eccentric (9) by 90° to the left. Marking has to
show in the direction of the outside wall.
3. Remove the nuts (61).
4. Remove the set-screw (45) and undo the screws (46) though
the base plate (13).
5. Remove the base plate (13).
6. Remove the toothed belt (11).
7. Remove the toothed belt (20).
8. Remove the bearings (20 / 21), fitting disks (39) and the
eccentric (9).
9. Base jaw clamping piece (10) and centering sleeves (62).
10. Remove the base jaw (4).