Maintenance
30
02.00 | PZH-SF 350 | Assembly and Operating Manual | en | 389485
6.4 Disassembly of the module
Position of the item numbers
Ø
Actuate the gripper to set it to "open" position.
Ø
Empty the compressed air lines.
Ø
Remove the screws (104) and the swivel jaw (3).
Ø
Take out the safety rings (130).
Ø
Loosen the screws (127) as well as the housing cover (126) with
bearings (105).
Ø
Mark the position of the tooth segments (8) on the pinion (110).
Ø
Take out the gear segments (8) together with the carrier plate
(7) and bearing (106).
Ø
Remove the safety rings (120).
Ø
Apply pressure to the piston chambers one after another to
push out the piston chamber covers (118).
WARNING
Make sure you take precautions to prevent uncontrolled
ejection of the piston covers!
Wear hearing protection!
Ø
Remove the screws (117), piston damper (116) and piston (10).
Ø
Remove the gear rack (9).
6.5 Servicing and assembling the product
Maintenance
• Clean all parts thoroughly and check for damage and wear.
• Treat all greased areas with lubricant.
• Oil or grease bare external steel parts.
• Replace all wear parts / seals.
– Position of the wearing parts
Assembly
Assembly takes place in the opposite order to disassembly.
Observe the following:
• Unless otherwise specified, secure all screws and nuts with
Loctite no. 243 and tighten with the appropriate tightening
torque.