Assembly
30
08.00 | PZN-plus | Assembly and Operating Manual | en | 0389374
5.3.8 Mounting programmable MMS-P 22 magnetic switch
NOTICE
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
NOTE
If there is no T-nut available, slide the sensor according to dimen-
sion I1 into the groove (2),
Setting dimensions
[
}
26].
Ø
Turn the sensor (1) into the groove (2).
OR: Slide the sensor (1) into the groove (2) until the sensor (1)
stops at the T-nut (3).
Ø
Secure the sensor (1) using the set-screw (4).
Tightening torque: 10 Ncm
Ø
Adjust sensor (1), see sensor assembly and operating manual.
5.3.9 Mounting the reed switch RMS 80
NOTICE
Blockade of the gripper after setting or replacing of the switch-
ing cam!
The switching cam can be tilt in the guide, if it was not fixed ex-
actly in the base jaw.
•
Apply the switching cam in the direction of the base jaw, so
that the cam does not contact the housing of the gripper.