Assembly
32
03.01/3-Finger Centric Gripper PZN-plus/en
B
A
B A
26
FPS-M8
7
23
38
17a
17
1
Fig. 15
In the version with dust cover Dust cover remove the sealing bolts
(85) first, in order that the flexible position sensor FPS-M8 can be
mounted. The cover (81) must be removed before the operating
cam can be replaced.
1 Remove the operating cam for monitoring along with the in-
ductive proximity switch (5) and the two screws (42 and 43)
from the base jaw (2 / 7).
2 With the chamfered side to the front, insert the operating cam
(21 / 23) into the base jaw (2 / 7) and screw it with the screw
provided (38).
3 First insert the spacer (26) and then flexible position sensor
FPS-M 8 through the bracket (17) into the special hole drilled
in the housing (1) to the stop, and clamp the sensor in this po-
sition by tightening the screw (18).
For setting sensor see separate user‘s manual of the sensor.
Monting of the
attachment kit