Maintenance and care
36
03.01/3-Finger Centric Gripper PZN-plus/en
Maintenance and care
Notes
DANGER
Danger of explosion in explosion risk areas!
•
Follow the instructions in supplementary sheet "Installation
and operating instructions - EX" for modules in explosion-
resistant versions (EX)!
Original spare parts
When replacing damaged parts (wearing parts/spare parts) only
use SCHUNK original spares.
Replacement of housing and base jaws
The base jaws and the guides in the housing are matched to each
other. To have these parts replaced, send the complete module
along with a repair order to SCHUNK.
Maintenance of module with gripping force maintenance "A.D.
gripping" (A.D.)
The pistons have to be aligned using an assembly device. There-
fore we recommend to have the module serviced and the seals re-
placed by SCHUNK.
If this is not possible, you can carry out the maintenance and re-
place the seals yourself.
Maintenance and lubrication intervals
NOTICE
Environmental temperatures of more than 60 °C/ 140 °F can
harden the used lubricants faster!
Lubrication and maintenance works have to be carried out more
often.
size
40 - 160
200 - 380
Interval [Mio. cycles]
10
5
Maintenance- and lubrication interval
9
9.1
9.2