Maintenance and care
03.01/3-Finger Centric Gripper PZN-plus/en
41
5 Mark the installation position between the cylinder piston (6)
and the housing (1). Undo the screw (40) and remove the cy-
linder piston (6) out of the housing (1).
6 Push the piston (3 / 8) upwards and out of the housing (1).
7 Pull the base jaw (2 / 7) out of the housing (1).
Variant with power booster cylinder (KVZ)
WARNING
Risk of injury when the machine/system moves unexpectedly!
Remove the energy supplies.
Make sure, that no residual energy remains in the system.
1 Remove air pressure lines.
WARNING
In the version with spring-loaded pressure piece, bear in mind
that this component is under spring tension.
2 Unscrew the screws (47) and then detach the cover plate (5).
3 Mark the installation position of the piston (3) and the base
jaws (2) in the housing (1).
4 Unscrew the screws (54 / 57) and then detach the cover (4).
5 Unscrew the screw (51) and remove the cylinder piston (6)
and spacer piston (66) from the intermediate housing (65).
6 Detach the intermediate housing (65).
7 Mark the installation position between the cylinder piston (6)
and the housing (1). Remove the second cylinder piston (6)
from the housing (1).
8 Push the piston (3 / 8) upwards and out of the housing (1).
9 Pull the base jaw (2 / 7) out of the housing (1).
9.4.5