Maintenance and care
01.01|RP / RW / RC 1212-2128|en
39
WARNING
Components for the maintenance of gripping force unit are un-
der spring tension (except for the GKS rod, item 2)
•
It is recommended to have damaged and defective modules
repaired in the production facility. Please consult your
SCHUNK contact person.
•
To remove the GKS spring, secure the lock washer and circlip
(GKS items 6, 8 and 9) with a suitable device against jumping
out.
•
Disassemble the module as shown in the "Assembly drawings",
•
Only disassemble the rotation module for repair purposes.
Assembling the module
WARNING
Risk of injury due to spring forces during the assembly of a com-
pletely disassembled GKS!
Install the spring, lock washer and circlip (GKS items 6, 8 and 9)
with an appropriate device.
•
Clean all parts thoroughly and check for damage and wear.
•
Treat all greased areas with lubricant.
•
Oil or grease bare external steel parts.
Assembly takes place in the opposite order to disassembly. Ob-
serve the following:
•
Unless otherwise specified, secure all screws and nuts with Loc-
tite no. 243 and tighten with the appropriate tightening torque.
Select suitable tightening torques for screws when assembling
the module in accordance with generally accepted guidelines
for screw connections.
11.4
Maintenance
Assembly