Assembly and settings
24
01.01|RP / RW / RC 1212-2128|en
End position monitoring
Two options are available for the end positions monitoring:
•
By magnet sensors MMS
•
By inductive sensors via standardized monitoring sets
With the MMS sensor, the magnet integrated in the piston is mo-
nitored.
NOTICE
Sensor can be damaged during assembly.
Do not exceed the maximum tightening torque of 10 Ncm for the
set screws.
Fig. 6 MQL sensor attachment
3.0
Max.
10 Ncm
Fig. 7
For monitoring of the two end positions, one sensor each is in-
stalled.
Piston is in the respective end position.
1 Turn the sensor into the groove.
2 Push the sensor into the groove until the signal is present at
the output.
3 Fix the magnetic switch into this position by tightening the
set-screw with the Allen key.
8.4.2
Attachment /
adjustment MMS
magnet sensors