Assembly and settings
12
05.00|RM 50 - 310 |en
Assembly and settings
NOTICE
Assembly measures
• When mounting loads, do not allow impermissible forces and
moments to be exerted (see catalog data).
• Select the suitable screw tightening torque when assembling
the module or loads at the module in accordance with the
generally accepted guidelines for screw connections.
• Secure all screws using a suitable chemical screw lock.
Mechanical connection
The values relate to the entire bolting surface.
Requirements for levelness of the bolting surface (Dimensions in mm)
Diameter
Permissible unevenness
< 100
< 0.02
> 100
< 0.05
The connection geometries are above, below and at the side of the
rotary module.
Dimensions for the position and size of the connection geometries,
☞
Catalog data sheet.
NOTE
• When mounting the module from the rear or on the side,
mount the module using the fixing bores provided.
• Mount the modules using the fixing bores provided.
7
7.1
Check the evenness
of the bolting surface
Mounting
www.comoso.com