Troubleshooting
18
05.00|RM 50 - 310 |en
Troubleshooting
Modul does not move?
Possible cause
Corrective action
Pressure drops below minimum.
Compressed air lines switched
Check compressed air lines.
Proximity switch defective or set incorrect. Repair the proximity switch.
Unused air connections not closed.
Close the unused air connections.
Choke valve closed.
Open the choke valve.
Does the module not travel through the rotating angle?
Possible cause
Corrective action
The end positions are incorrectly adjusted
Pressure drops below minimum.
Check the air supply.
Mounting surface is not even enough
Check the levelness of the bolting surface.
Component is broken, e.g. through over-
loading
Send the module to SCHUNK with a repair
order or disassemble module
Shock absorber defective
Check or, if need be, replace the shock ab-
sorber
End position signal not present?
Possible cause
Corrective action
Precisely adjust the sensor for the stop
Proximity switch defective or set incorrect. Repair the proximity switch.
Cable breakage
Replacing the sensor cable