Assembly
30
02.00|ROTA NCA |en
Checking the chuck mount
The machine side must be aligned prior to the flange being
installed in order to achieve high concentricity of the chuck. To do
this, check the contact surfaces on the spindle for concentricity
and axial run-out accuracy using a dial indicator.
There should be a maximum concentricity error in the centering
of the mount of 0.005 mm and a maximum axial run-out error in
the contact surfaces of 0.005 mm. The flat surface of the spindle
must also be checked for flatness using a straightedge.
Make sure that the surface area of the flat surface is deburred at
the bore holes and is clean.
5.3