Maintenance
01.00|ROTA THW vario |en-US
53
NOTICE
During this procedure, all three segments should be lubricated
evenly in order to avoid large imbalances.
WARNING
Slipping when lubricating with a piston grease gun can cause
serious cuts!
Maintenance plan
The previous sections describe the maintenance work required for
optimum and trouble-free operation.
If increased wear and tear can be detected during regular checks,
shorten the required maintenance intervals according to the
actual signs of wear and tear.
Contact SCHUNK if you have any questions about maintenance
work and intervals.
Cleaning interval
Maintenance work
daily
Visual inspection and complete cleaning in case of
weekly
Cleaning adaptation clamping device
Lubrication interval
Demands
every 20 hours
every 8 hours
1000 - 1500 hours
Full cleaning with disassembly of chuck depending
on type of contamination and quantity
NOTE
Pre-filtering with double switch filter (machine width 100 µm, PI
3754) is necessary for proper functioning of the coolant supply.
The double switch filter is mounted on the coolant cleaning
system.