3.3 Fluid consumption
Operating data for compressed air connection
Pitches
4
6
8
12
16
RST-D 60
Fluid consumption per cycle [cm
3
]
21
14
11
7.5
-
RST-D 87
Fluid consumption per cycle [cm
3
]
53
36
27.5
19
-
RST-D 134
Fluid consumption per cycle [cm
3
]
198
135
103
71
55
NOTICE
Material damage if oil-free compressed air is used incorrectly!
The product may be damaged if the factory-applied lubrication is
washed off.
•
Operating with oil-free compressed air is not permitted if the
product was already used with oiled compressed air.