Troubleshooting
36
04.00 | RST-D | Assembly and Operating Manual | en | 389517
7 Troubleshooting
7.1 Ring indexing table does not pulsing
Possible cause
Corrective action
Pressure drops below minimum.
Check air supply.
Pressure lines connected incorrectly.
Check compressed air lines.
Component part defective.
Replace component or send it to SCHUNK
for repair.
Product does not lock correctly
Ring indexing table does not lock correctly
[
7.2 Ring indexing table does not lock correctly
Possible cause
Corrective action
Damper turned in too far (piston does not
reach end position).
Readjust absorbers.
Setting the end position dampers
Pressure drops below minimum.
Check air supply.
7.3 Signal for piston position or zero point cycle ring monitoring
missing
Possible cause
Corrective action
Zero point monitoring sensor set incorrectly. Adjust sensor or if necessary change sensor.
Piston position monitoring sensor set
incorrectly.
Adjust sensor or if necessary change sensor.
Proximity switch defective or set incorrect.
Change sensor.
Cable breakage.
Replace connection cable for sensor.
7.4 Ring indexing table hitting in end positions
Possible cause
Corrective action
Damping wrong adjustet.
Readjust absorbers.
Setting the end position dampers
Readjust back stop.
Setting the end position dampers
Shock absorber defective.
Change the shock absorber.
Setting the end position dampers
Exhaust throttle defective.
Replacing the exhaust air throttle.
Swiveling speed too high.
Check swiveling time and adjust with
exhaust air throttles as necessary.