Troubleshooting
24
01.02|SPG 100|en
Module does not achieve the opening and closing times?
Possible cause
Corrective action
Compressed air lines are not installed
optimally.
If present: Open the flow control couplings on
the module to the maximum that the movement
of the jaws occurs without bouncing and hitting.
Check compressed air lines.
Inner diameter of the compressed air lines are
sufficiently large relative to the compressed air
consumption
Compressed air lines between module and
control valve shoud be kept as short as possible.
Flow rate of valve is sufficiently large relative to
the compressed air consumption.
NOTICE! The one-way flow control valves must
not be removed even when the gripper has not
reached the opening and closing times.
If, despite of optimal air connections, the
opening and closing times are not achieved
according to the catalog, we recommend the use
of quick exhaust valves direct at the module.
Load too high
Review permissible weight and length of the
jaws.
8.5