Maintenance and Care
01.02|SPG 100|en
25
Maintenance and Care
Notes
Original spare parts
When replacing damaged parts (wearing parts/spare parts) only
use SCHUNK original spares.
Replacement of housing and base jaws
The base jaws and the guides in the housing are matched to each
other. To have these parts replaced, send the complete module
along with a repair order to SCHUNK.
Maintenance and service intervals
NOTICE
At ambient temperature above 60°C the lubricants can
harden faster.
• Interval decrease accordingly.
Interval [Mio. cycles]
0,5
Lubricants/Lubrication points (basic lubrication)
We recommend the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point
Lubricant
Metallic sliding surfaces
LINOMAX
All seals
Renolit HLT 2
Bores on the piston
Renolit HLT 2
In addition to the described maintenance, the guides of the
gripper can be re-lubricated as needed by means of lubricating
nipples. The lubricating nipples can be used instead of the air
purge connection.
Remove the two set screws for the air purge connection and
replace them with two conical grease nipples.
9
9.1
9.2
9.3
www.comoso.com