Assembly and settings
5.4.2 Assemble inductive proximity switch IN 80
Mounting kit for inductive proximity switch
NOTE
Holders (3) and screw (4) are pre-assembled at the factory.
1. Connect sensor and secure cable, see Sensor Assembly and
Operating Manual.
2. Push sensors (1) and (6) up to the stop in the holders (3) and
clamp them in this position with screws (2).
3. Make sure that screw (4) is positioned centrally under the
sensor.
4. Loosen screws (5) on the holder (3). Adjust the holder (3) in
such a way that sensor (1) responds. Re-tighten screws (5).
5. Swivel the product by 180°.
6. Adjust the holder of sensor (6) in the same way.
7. Check the switching positions and test the function, re-adjust
the position if necessary.
33
03.00 | SRH-plus-D | Assembly and Operating Manual | en | 1424337